45mm 60mm Endoscopic Stapler Reloads Linear Stapler Cartridge Gripping Surface Technology


Features of Endoscopic Linear Cutter Reloads
● The high-hardness alloy of the cutter head is quenched to ensure sharpness and more complete cutting structure;
●Better tissue thickness adaptability;
● Larger rotation angle, more convenient operation;
● Flat the height of the reloads, evenly anastomosis, reduce tissue damage;
● It has a large pre-clamping force, which is conducive to squeezing the tissue and ensures good anastomosis.
Model specifications and dimensions(Linear Stapler Cartridges )
Model Specification | Anastomosis length(mm) | Nail height(mm) | Color |
ESA60-2.6 | 60 | 2.6 | White |
ESA60-3.6 | 60 | 3.6 | Blue |
ESA60-3.8 | 60 | 3.8 | Gold |
ESA60-4.1 | 60 | 4.1 | Green |
ESA60-4.2 | 60 | 4.2 | Black |
ESA45-2.6 | 46 | 2.6 | White |
ESA45-3.6 | 46 | 3.6 | Blue |
ESA45-3.8 | 46 | 3.8 | Gold |
ESA45-4.1 | 46 | 4.1 | Green |
ESA45-4.2 | 46 | 4.2 | Black |
• Staple 2.0mm should not be used for tissue with a thickness less than 0.6mm after compression. or tissue and aorta properly compressed to 1.0mm thickness.
• Staple 2.6mm should not be used for tissue with a thickness less than 1mm after compression. or tissue and aorta properly compressed to 1.5mm thickness.
• Staple 3.6m should not be used for tissue with a thickness less than 1.5mm after compression. or tissue and aorta properly compressed to 2.0mm thickness.
• Staple 4.2mm should not be used for tissue with a thickness less than 2.0mm after compression. or tissue and aorta properly compressed to 2.5mm thickness.
Advantage(Linear Stapler Cartridges )
Fine Pressing
Double guiding
Perfectly formed nails
Fine Pressure System - for thick tissue
Nail bin guide structure
- Nail compartment surface gripping technology for better and non-invasive grip on the tissue
The surface gripping technology of the nail compartment enables a better and non-invasive grip on the tissue, supports and secures the nail and reduces lateral/longitudinal oscillations when the nail is lifted.
supports and secures the staple, reduces lateral/longitudinal wobble when the staple is lifted, allows it to enter the stapling groove, and keeps the tissue in place during firing.
Tissue stays in place during firing
- Reduced tissue spillage for accurate cutting and better nail formation.
The "teardrop" shaped nail groove in the nail holder makes B-type nails more accurate during firing. More precise nail formation, less bleeding, and more secure seams.
"Teardrop" nail slot design
Caveat
1. 12 shots
2. Dwell for 15 seconds
3. 60mm and 45mm stitch lengths.
4. 6 rows of staples throughout the product line
5. Passes through a 12 mm trocar (Except Convidien's Trocar).
6. The instruments do not have a pre-loaded staple compartment.
7. Single patient single use
8. Cleaning of residual staples, recommended procedure:
-Step 1: Submerge the jaws in water and rinse.
-Step 2: Wipe the jaws carefully with gauze.
Service:
We can accept OEM for any requirements
ECR60 Echelon Reload Endoscopic linear cutter Stapler is suitable for resection, transection and anastomosis of lung, bronchial tissue, stomach and intestinal in open or endoscopic surgery. Be applicable in thoracic surgery, abdominal surgery and gynecologic endoscopy.